Tenmars TM-192 Magnetic Field Meter

YSH-174-999
Tenmars TM-192 Magnetic Field Meter

Key features of Tenmars TM-192 Magnetic Field Meter

• ELF magnetic field measurement over a 30-2000 Hz frequency range
• Triaxial X, Y, Z sensor, measurement independent of measurement angle
• Ranges: 20/200/2000 mG and 2/20/200 uT
• Resolution: 0.01/0.1/1 mG or 0.001/0.01/0.1 uT
• Auto and manual range selection with HOLD, MAX and MIN functions
• Data logging memory with a capacity of 500 data sets
• 2.5 samples/second sample rate, time and calendar functions
• Includes user's manual, 9 V battery and carrying case

Gross price (including 27% VAT): 162.52€ (Net price: 127.96€)
Add to Cart Price Watch
You can ask for e-mail price notifications when the price of this product gets under a limit you specify. To use this feature you need to have a user account and to be signed in.

Further details of Tenmars TM-192 Magnetic Field Meter

The Tenmars TM-192 is a hand-held instrument for measuring extremely low frequency, ELF magnetic fields over a frequency range of 30-2000 Hz. It uses three internal orthogonal sensors for measurements on the X, Y and Z axes, making measurement independent of measurement angle. The instrument can be used to measure magnetic fields around electric transmission equipment, power lines, microwave ovens, air conditioners, refrigerators, computer monitors, video and audio devices, home appliances and industrial devices.

Tenmars TM-192 triaxial ELF magnetic field meter

• Frequency response: 30-2000 Hz
• Sensor: Triple Axis, X, Y and Z
• Internal sensors: three orthogonal sensors
• Ranges: 20/200/2000 mG and 2/20/200 uT
• Resolution: 0.01/0.1/1 mG or 0.001/0.01/0.1 uT
• Display units: mG and uT
• Display: 4-digit Triple LCD display
• Sample rate: 2.5 times per second
• Overload indication: OL


By default, the instrument displays the triaxial total magnetic field reading. The controls allow switching between the three independent X, Y and Z single-axis magnetic field readings and the triaxial total magnetic field reading.

TM-192 measurement accuracy and ranges

• Accuracy at 20 mG/2 uT range at 50/60 Hz: +/-(3.0% + 30 digits)
• Accuracy at 200 mG/20 uT and 2000 mG/200 uT ranges at 50/60 Hz: +/-(2.5% + 5 digits)
• Accuracy over 30-2000 Hz: +/-(5% + 5 digits)
• Auto range selection
• Manual range selection


When manual range mode is selected, the LCD displays OL if the reading is overloaded. A higher measurement range can then be selected.

Tenmars TM-192 HOLD, MAX and MIN functions

• Data Hold, HOLD function for retaining the displayed reading
• Maximum Hold, MAX function
• Minimum Hold, MIN function
• In MAX mode, the displayed reading updates to retain the maximum value
• MIN mode retains the minimum value


In addition to retaining the current displayed reading, the TM-192 provides functions for retaining the maximum and minimum values occurring during measurement.

TM-192 data logging with 500 data sets

• Memory capacity: 500 data sets
• Manual storage of individual readings
• A time stamp can be stored with the displayed reading
• Continuous data logging
• Adjustable data logging interval: 2 seconds to 24 hours 59 minutes 59 seconds
• Continuous data logging can be disabled
• Logged readings can be viewed on the instrument
• Forward and backward scrolling through stored readings
• Last recorded data set can be deleted
• Entire data logger memory can be cleared


For continuous data logging, the interval between data records can be configured. Setting the interval to 00 hours 00 minutes 00 seconds disables continuous data logging. For a single data memory record, the displayed reading and its time stamp are stored in memory.

Tenmars TM-192 time, calendar and auto power-off functions

• Time function
• Calendar function
• 24-hour time format
• Auto power-off
• Default auto power-off time: 5 minutes
• Adjustable auto power-off time: 0-99 minutes
• Setting 0 minutes disables auto power-off
• Low battery indication


The automatic power-off time can be adjusted between 0 and 99 minutes. When the low battery indication appears, the 9 V battery must be replaced immediately.

TM-192 controls and connections

• LCD display
• Power key
• MAX/MIN key
• Data Hold key
• Record data and setup function left key
• Range and setup function up key
• Reading and setup function right key
• Setup function key
• Units and setup function down key
• Enter key
• Calibration points for Triple Axis
• External 9 V DC power connection
• Tripod mounting screw
• Battery cover


The instrument can also be operated from an external DC power supply. The TM-192 does not include the USB PC interface documented for the TM-192D model.

Tenmars TM-192 external power supply

• External AC to DC adapter nominal voltage: 9 V DC
• Permitted external supply voltage: 8-14 V DC maximum
• Required supply current: greater than 300 mA DC
• Connector external diameter: 5.5 mm
• Connector internal diameter: 2.1 mm
• Connector polarity: centre pin positive, external casing ground


The instrument itself is powered by a 9 V battery. Approximate battery life is 100 hours.

TM-192 physical and environmental specifications

• Power supply: 9 V battery
• Battery life: approximately 100 hours
• Operating temperature: 5-40 C
• Operating relative humidity: below 80% RH
• Storage temperature: -10-60 C
• Storage relative humidity: below 70%
• Operating altitude: up to 2000 m
• Operating environment: indoor use
• Pollution degree: 2
• Weight: approximately 230 g
• Dimensions: 173 x 80 x 32 mm


Use a soft, dry cloth to clean the instrument. Do not use a wet cloth, solvents or water.

Tenmars TM-192 measurement procedure

• Measurement units can be selected between mG and uT
• Position the front of the meter towards the magnetic field to be measured
• Move the instrument slowly towards the object under measurement
• Field intensity may increase as the instrument moves closer to the object
• If the object is switched off during measurement, the reading should return to zero unless an electromagnetic field from another source is detected


Due to magnetic interference from environmental factors, the magnetic field meter may display a reading greater than 0.5 mG before measurement. This does not indicate a malfunction of the instrument.

Tenmars TM-192 applications

• Electric transmission equipment
• Power lines
• Microwave ovens
• Air conditioners
• Refrigerators
• Computer monitors
• Video and audio devices
• Home appliances
• Industrial devices


The TM-192 uses its triaxial sensor system to measure ELF magnetic fields from 30-2000 Hz. It provides mG and uT display units, auto and manual range selection, HOLD, MAX and MIN functions, and internal memory for 500 data sets.

TM-192 scope of delivery

• Tenmars TM-192 magnetic field meter
• User's manual
• 9 V battery
• Carrying case


The TM-192 is a 230 g hand-held ELF magnetic field meter with three orthogonal X, Y and Z sensors, a 500-data-set logging memory, time and calendar functions, and automatic power-off.