Safe & Sound EM3 Handheld Electric and Magnetic Fields Detector
Key features of Safe & Sound EM3 Handheld Electric and Magnetic Fields Detector
• Measures 3D AC magnetic, 1D AC electric fields and body voltage
• AC magnetic field: 16.7 Hz, 50 Hz-120 kHz, +/-1 dB
• AC electric field: 16.7 Hz, 50 Hz-400 kHz, +/-1 dB at 0.01-10 V/m
• Magnetic range: 0.01-100 mG per axis, max. 173 mG in 3D
• Body voltage: 1-12,000 mV, 50 Hz-120 kHz
• 16.7 Hz, >60 Hz, >2 kHz and FULL filters, RMS and PEAK modes
• Sound output and continuous operation via USB-C power
• Includes test leads, hand probe, grounding accessories and 2 AA batteries
Further details of Safe & Sound EM3 Handheld Electric and Magnetic Fields Detector
The Safe and Sound EM3 combines 3D AC magnetic field, 1D AC electric field and body voltage measurements in a single instrument. The meter is optimized for measuring low-level AC magnetic and AC electric fields. It is suitable for home and professional use and meets the Building Biology SBM-2015 and SBM-2024 guidelines for electromagnetic sensitivity.
Safe and Sound EM3 AC magnetic field measurement
• AC magnetic field frequency response: +/-1 dB at 16.7 Hz and from 50 Hz-120 kHz, within the 0.01-25 mG or 1-2500 nT range
• With reduced tolerance, the measurement range extends up to 100 mG or 10,000 nT per axis
• With reduced tolerance, 3D measurement extends up to 173 mG or 17,300 nT
• Magnetic field strength range: 0.01-100 mG, frequency dependent, 1 axis
• 3D magnetic measurement range: 0.01-173 mG, 3 axes
• Magnetic fields are measured on three axes: X, Y and Z
The EM3 uses three magnetic field sensors. The three sensors register magnetic fields relative to the X, Y and Z axes.
Safe and Sound EM3 AC electric field measurement
• AC electric field frequency response: +/-1 dB at 16.7 Hz and from 50 Hz-400 kHz, within the 0.01-10 V/m range
• AC electric field frequency response: +/-1 dB at 16.7 Hz and from 50 Hz-120 kHz, within the 0.01-approximately 45 V/m range
• With reduced tolerance, the measurement range extends up to 200 V/m
• Electric field strength range: 0.01-200 V/m, frequency dependent
• Electric fields are measured on 1 axis, the Y axis
The EM3 uses single-axis sensing for AC electric field measurements. Cables for grounded electric field measurements are also included.
Safe and Sound EM3 body voltage measurement
• Body voltage measurement range: 1-12,000 mV
• Body voltage frequency range: 50 Hz-120 kHz
• Cables required for body voltage readings are included
Body voltage measurement indicates AC electric field exposure on the human body and is not a direct measurement of electric fields in the environment. The measurement procedure takes a voltage reading between a person and a dedicated ground point.
EM3 filters and measurement modes
• 16.7 Hz filter
• >60 Hz filter
• >2 kHz filter
• FULL mode without filters
• RMS measurement mode
• PEAK measurement mode
• Sound output
The selectable filters provide dedicated measurement options for 16.7 Hz, frequencies above 60 Hz and frequencies above 2 kHz, as well as unfiltered FULL measurement. Both RMS and PEAK measurement modes are available.
Safe and Sound EM3 sound output and operation
• Audio output uses a Geiger counter effect
• Clicks vary with measured power
• Clear mode indicators
• Compact enclosure
• Continuous operation via USB-C power
• Power supply: 2 AA alkaline batteries
• Third-party tested
The EM3 has a compact size matching the other meters in the Safe and Sound series. The instrument can also operate continuously via USB-C power.
Safe and Sound EM3 package contents
• Safe and Sound EM3 meter
• EM3 case
• Safe and Sound EM3 measuring instructions
• User's guide
• Certificate of calibration
• 46 cm red test lead for hand probe with 4 mm banana connector
• 6.1 m black test lead for grounding with 4 mm banana connector
• 4-inch polished solid aluminum hand probe
• Ground plug for a 120 VAC electrical outlet
• Alligator ground clip with 4 mm banana connector
• Outlet tester
• 20 cm ground peg
• 2 AA alkaline batteries
• 2-year warranty
The Safe and Sound EM3 combines three measurement functions, multiple selectable frequency filters, RMS and PEAK measurement modes, and sound output. The package also includes the test leads, hand probe and grounding accessories required for grounded electric field and body voltage measurements.